Introduction to Indian Standard IS 7098 (Part 2) cover Crosslinked polyethylene insulated Thermoplastics sheathed cables (3.3-33kV). This standard specifies the manufacturing, chemical and physical requirements and testing of Crosslinked polyethylene insulated Thermoplastics sheathed cables (3.3-33kV).
Specification of IS 7098 PART 2
IS 7098 (Part 2) specifies the quality parameters or characteristics of the Crosslinked polyethylene insulated Thermoplastics sheathed cables (3.3-33kV) as follows
Purity test of copper
Conductor Resistance
High voltage test
Armour Resistance
Annealing Test
Tensile test
Wrapping test
Thickness of Insulation Sheath
Tensile Strength and elongation of insulation and sheath
Insulation Resistance
Shrinkage test
Hot deformation test
Heat Shock test
Cold bend test
Cold impact test
Thermal Stability
Flammability Test
Flame Retardance
Temperature Index
Smoke density
Mandate for ISI Mark Certification of Crosslinked polyethylene insulated Thermoplastics sheathed cables (3.3-33kV) (IS 7098 (Part 2)) :
Under section 14 of Bureau of Indian Standards Act, 1986 (63 of 1986), the Ministry of Commerce and Industry, Department for Promotion of Industry and Internal Trade after consulting the Bureau of Indian Standards has issued the Quality control order.
As per the Quality control order, all the manufacturers of Crosslinked polyethylene insulated Thermoplastics sheathed cables (3.3-33kV) are obligated to obtain
ISI Mark Certification.
Types of Polyethylene Insulated covered under IS 7098 (Part 2)
|
“Licence is granted to use Standard Mark on Crosslinked polyethylene insulated Thermoplastics sheathed cables (3.3-33kV) as per IS 7098 (Part 2): 1988”.
|
|
Types / Scope of License
|
Cross-linked Polyethylene Insulated, PVC/Polyethylene Sheathed Cables for Single Phase or Three Phase (earthed and unearthed) systems for electricity supply purposes, Armoured/Unarmored, Screened/Unscreened, with Aluminium/Copper Conductor, Category 01/C1/C2, except/suitable for use in mines, excluding/including Low Temperature Applications, with/ without Water Tight Construction for working voltages up to and including …. kV for the following sizes
a) Single core for Sizes up to and including ….. mm².
b) Three-core for Sizes up to and including ….. mm²
|
Procedure to obtain BIS Certification of Crosslinked polyethene insulated Thermoplastics sheathed cables (
Requirements to get the BIS license for Crosslinked polyethylene insulated Thermoplastics sheathed cables (3.3-33kV)
- Conformity of Raw Material as per IS 7098 (Part 2)
- In-house testing laboratory for mandatory tests
- Competent Quality Control Personnel
- Adherence to the BIS guidelines for Polyethylene Insulated Thermoplastics Sheathed Cables as per Indian standard IS 7098 (Part 2)
- There are 3 major categories of document required to get the BIS license:
- Administrative Details
- Technical Details
- Quality Control Personnel Details
- Commercial Details
ISI/BIS Licensing for IS 7098 PART 2
Expenses involved in obtaining BIS certificate for Crosslinked polyethylene insulated Thermoplastics sheathed cables (3.3-33kV) as per IS 7098 (Part 2) under the Product Certification (Scheme-I) of BIS :
|
S No.
|
Particular
|
Amount (INR)
|
Remarks
|
|
1.
|
Application Fee
|
1000
|
To be paid directly to BIS
|
|
2.
|
Audit Fee
|
7000
|
To be paid directly to BIS
|
|
3.
|
License Fee
|
1000
|
To be paid directly to BIS
|
|
4.
|
Sample Testing Fee
|
As Applicable
|
To be paid directly to BIS (Testing charges vary from product to product and lab to lab.)
|
|
5.
|
Minimum Advance Marking Fee
|
As per actual
|
To be paid directly to BIS (Marking fee varies as per Indian Standard.)
|
|
6.
|
Renewal Fee
|
1000
|
To be paid directly to BIS
|
|
7.
|
Inclusion Fee
|
5000
|
To be paid directly to BIS
|
|
8.
|
ERCS Pvt Ltd Service Fee
|
Please contact info@elitasrcs.com
|
- In the certification process, product testing is the most important stage as it determines whether the quality of the product meets Indian standards.
- For the same purpose, investments in testing facilities are required to install test equipment for internal factory test laboratories.
- Apart from charges mentioned above in the table, we may ask you to pay/reimbursement for a Pre-Visit at your Factory Premises to ensure the conformity of your product as per the relevant Indian Standard & BIS guidelines for its BIS certification.
Role of ERCS Private Limited in getting your product certified :
- To get BIS certification and produce a standard quality product, the manufacturer must ensure that their product must follow the specified Indian Standard Specifications (ISS) which we directly interpret to you from the BIS officials as per the Indian Standards.
- ECRS Private Limited will be your friend, philosopher and guide in the whole process of getting your product certified by the concerned authorities/ departments.
Scope of work by ECRS Private Limited:
- Ensuring the conformity of your product as per IS 7098 (Part 2):
ERCS Pvt. Ltd. has developed a vast network within the Electrical Industry & various BIS departments to assist for ensuring conformity of the product Crosslinked polyethylene insulated Thermoplastics sheathed cables (3.3-33kV) according to according to IS 7098 (Part 2).
- Effective documentation with the awareness of the BIS guidelines:
In order to facilitate the manufacturing industry in obtaining BIS certifications, guidelines have been developed. Our team has the experience of completing over 150 projects and technically competent acquaintances in various Industries.
We are familiar with the Indian Standard Specifications & BIS guidelines and deliver the most suitable interpretation to the Quality Control Personnel so we can do a reliable and effective documentation of your product in accordance with the BIS guidelines.
- A pre-visit can be paid at your factory premises:
In the process of getting BIS certification, the officer from BIS authority visits the factory for inspection. In order to get good results, the BIS inspection should go smoothly without any Non-Conformity. By keeping this goal in mind, our team will organize a pre-visit to your factory premises so that required changes can be adapted so as to remove the elements of fallibility.
- Assistance for BIS audits:
We will explain the whole procedure of conducting a BIS inspection and make you aware of the things which need to be prepared and readily available at the time of inspection.
Benefits of getting ISI Mark for Crosslinked polyethylene insulated Thermoplastics sheathed cables (3.3-33kV)
- The term “ISI mark" means, that a certain product conforms to the quality standards set up by the government.
- It is compulsory for Crosslinked polyethylene insulated Thermoplastics sheathed cables (3.3-33kV) to obtain the ISI Mark and the violators are penalized with the material seize and a significant sum as fine.
- Getting certification improves the probability of your product to survive and compete in the market.
- Customers have the tendency of buying ISI certified products as it ensured safety and standard quality. Hence, with the certified products you can win the confidence and trust of the buyer.
- With the word of mouth of such client list, you can establish your credibility in the market.
- Hence with the renowned brand, you can raise the standard and benchmark the market value of the product.